Siemens SINUMERIK codes
Siemens SINUMERIKServo/AxisAdvanced45-90 minutes

16933

Siemens 16933 - Interrupt treatment: action <ALNX> not allowed in the current state

Interrupt treatment: action <ALNX> not allowed in the current state

If a temporary standstill has occurred because of a Reorg event across block boundaries, it is possible that a block without Reorg capability has been loaded. In this situation, it is unfortunately necessary to abort the Reorg event handling! Reorg events are, e.g. abort subprogram, delete distance-to-go and interrupts Control reaction: NC Start disable in this channel. Interface signals are set. Alarm display. NC Stop on alarm.

Safety

  • Only qualified personnel should diagnose and clear control alarms; follow the machine builder's safety procedures and lockout/tagout where hardware work is required.

Common Causes

  • If a temporary standstill has occurred because of a Reorg event across block boundaries, it is possible that a block without Reorg capability has been loaded.
  • In this situation, it is unfortunately necessary to abort the Reorg event handling!
  • Reorg events are, e.g. abort subprogram, delete distance-to-go and interrupts

Troubleshooting Steps

  1. 1Abort program with the RESET key.
  2. 2Clear alarm with the RESET key. Restart part program

Seeing Multiple Alarms?

Seeing another alarm with this one? Enter the code.

Get machine-aware diagnosis

AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.

Start free

Was this guide helpful?

Always verify with your machine manual or a certified technician before performing service procedures.