Siemens SINUMERIK codes
Siemens SINUMERIKServo/AxisIntermediate20-45 minutes

15166

Siemens 840D 15166 - Channel user system asup _N_ASUP_SPF not available

Channel user system asup _N_ASUP_SPF not available

By means of the machine data 11610 $MN_ASUP_EDITABLE the function "User-defined system asup" has been activated. However, the relevant user program could not be found in the specified search path: - 1. /_N_CUS_DIR/_N_ASUP_SPF - 2. /_N_CMA_DIR/_N_ASUP_SPF The default system asups are used.

Safety

  • Refer to Siemens documentation
  • Ensure qualified technician performs repairs

Common Causes

  • User-defined ASUP file _N_ASUP_SPF not created or placed in incorrect directory path
  • Machine data 11610 $MN_ASUP_EDITABLE enabled but corresponding SPF program missing from both search paths
  • File naming convention incorrect - must be exactly _N_ASUP_SPF without additional extensions or characters
  • Directory permissions preventing access to /_N_CUS_DIR or /_N_CMA_DIR search paths
  • User program file corrupted or incomplete upload to the CNC control

Troubleshooting Steps

  1. 1Verify machine data 11610 $MN_ASUP_EDITABLE setting - confirm if user-defined ASUP is actually required; consider disabling if not needed to revert to default system ASUP
  2. 2Check both search paths on the control: /_N_CUS_DIR/_N_ASUP_SPF and /_N_CMA_DIR/_N_ASUP_SPF using file manager or HMI directory browser to confirm file existence and exact naming
  3. 3If file missing, create or transfer the _N_ASUP_SPF program to the correct directory using DNC or SINUMERIK Operate file transfer; verify file is complete and not truncated
  4. 4Inspect file permissions on the control filesystem - ensure user account has read/execute access to both search directories and the SPF file itself
  5. 5Disable and re-enable machine data 11610 to force the control to re-scan for the user program, or perform a controlled restart if the file was just added

Seeing Multiple Alarms?

Seeing another alarm with this one? Enter the code.

Get machine-aware diagnosis

AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.

Start free

Was this guide helpful?

Always verify with your machine manual or a certified technician before performing service procedures.