Siemens SINUMERIK codes
Siemens SINUMERIKServo/AxisIntermediate30-60 minutes

15186

Siemens 15186 - errors in GUD, macro or INI file

errors in GUD, macro or INI file

errors were found when processing GUD/macro definition files (DEF files) or initialization files (INI files) Alarm 15180 has already informed about the corresponding file. Prior to that the errors shown were reported by error-specific alarms, e.g. 12080 "syntax error" Control reaction: NC Start disable in this channel. Interface signals are set. Alarm display.

Safety

  • Only qualified personnel should diagnose and clear control alarms; follow the machine builder's safety procedures and lockout/tagout where hardware work is required.

Common Causes

  • %2 errors were found when processing GUD/macro definition files (DEF files) or initialization files (INI files) Alarm 15180 has already informed about the corresponding file.
  • Prior to that the errors shown were reported by error-specific alarms, e.g. 12080 "syntax error"

Troubleshooting Steps

  1. 1Modify definition file or initialization file
  2. 2Clear alarm with the RESET key. Restart part program

Seeing Multiple Alarms?

Seeing another alarm with this one? Enter the code.

Get machine-aware diagnosis

AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.

Start free

Was this guide helpful?

Always verify with your machine manual or a certified technician before performing service procedures.