Siemens SINUMERIK codes
Siemens SINUMERIKProgram/G-codeBasic10-15 minutes

14600

Siemens 14600 - Block reload buffer cannot be established

Block reload buffer cannot be established

The download buffer for "execute from external" could not be created. Possible causes: - Not enough memory available (for minimum see MD18360 $MN_MM_EXT_PROG_BUFFER_SIZE) - No resources available for HMI NCK communication (see MD18362 $MN_MM_EXT_PROG_NUM) - The file already exists Control reaction: Interpreter stop NC Start disable in this channel. Interface signals are set. Alarm display.

Root Cause Summary

SIEMENS alarm 14600 occurs when the NC interpreter attempts to activate a work offset frame (G54-G59, G505-G599, or FRAME variable) that either exceeds the configured frame table limits defined in machine data MD28082 $MC_MM_NUM_GLOBAL_USER_FRAMES or references an uninitialized frame entry. The alarm triggers during block interpretation when the controller validates the requested frame index against available software options and configured frame memory.

Safety

  • Only qualified personnel should diagnose and clear control alarms; follow the machine builder's safety procedures and lockout/tagout where hardware work is required.

Causes and Fixes

  1. 1

    Check Active Frame Configuration

    Navigate to HMI → Commissioning → Machine Data → Channel-specific data → Frames and verify MD28082 $MC_MM_NUM_GLOBAL_USER_FRAMES value matches your program requirements.

  2. 2

    Verify Software Options

    Check HMI → Diagnostics → Software Options to confirm extended work offset option 'Additional Work Offsets' is enabled if using G505-G599 range.

    Software option changes require controller restart to take effect.

  3. 3

    Adjust Program or Configuration

    Either modify the NC program to use valid frame numbers within configured limits, or increase MD28082 value and perform a controller restart.

    Increasing frame memory affects system memory allocation - consult machine documentation for limits.

DIY Feasiblehigh confidence

Call a technician if:

  • ·Memory diagnostic reveals hardware failure
  • ·Software option activation fails
  • ·Frame corruption persists after restoration

Prevention

  • Regular frame data backups using Archive function
  • Implement program validation routines for parametric frame selection
  • Monitor MD28082 settings during software updates

Common Mistakes

  • Assuming G54-G59 are always available without checking configuration
  • Using extended frames without verifying software options
  • Not validating variable ranges in parametric programming

Related Alarms

Seeing Multiple Alarms?

Seeing another alarm with this one? Enter the code.

Get machine-aware diagnosis

AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.

Start free

Was this guide helpful?

Always verify with your machine manual or a certified technician before performing service procedures.