Siemens SINUMERIK codes
Siemens SINUMERIKProgram/G-codeIntermediate20-40 minutes

14134

Siemens 14134 - Block G code for orientation interpolation not allowed

Block G code for orientation interpolation not allowed

It will only be possible to program a G code of the 51st G code group, if MD21104 $MC_ORI_IPO_WITH_G_CODE has been set to TRUE Control reaction: Interpreter stop NC Start disable in this channel. Interface signals are set. Alarm display.

Safety

  • Only qualified personnel should diagnose and clear control alarms; follow the machine builder's safety procedures and lockout/tagout where hardware work is required.

Common Causes

  • It will only be possible to program a G code of the 51st G code group, if MD21104 $MC_ORI_IPO_WITH_G_CODE has been set to TRUE

Troubleshooting Steps

  1. 1Adapt machine data.
  2. 2Clear alarm with the RESET key. Restart part program

Seeing Multiple Alarms?

Seeing another alarm with this one? Enter the code.

Get machine-aware diagnosis

AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.

Start free

Was this guide helpful?

Always verify with your machine manual or a certified technician before performing service procedures.