14098

Siemens 14098 - Block conversion error: no valid number found

Block conversion error: no valid number found

The string is not a valid INT or REAL number Control reaction: Interpreter stop NC Start disable in this channel. Interface signals are set. Alarm display.

Safety

  • Only qualified personnel should diagnose and clear control alarms; follow the machine builder's safety procedures and lockout/tagout where hardware work is required.

Common Causes

  • The string is not a valid INT or REAL number

Troubleshooting Steps

  1. 1Modify part program.
  2. 2If it is an entry, then you can check whether the string is a number via the preset function ISNUMBER (with the same parameter).
  3. 3Clear alarm with the RESET key. Restart part program