Siemens SINUMERIK codes
Siemens SINUMERIKProgram/G-codeIntermediate30-120 minutes

129943

Siemens 129943 - : Invalid configuration of $AN_TIMER.

: Invalid configuration of $AN_TIMER.

Setting AN_TIMER_Nr of section [DAT] in ITS.INI is incompatible with the setting in machine data 18710 $MN_MM_NUM_AN_TIMER

Safety

  • Only qualified personnel should diagnose and clear control alarms; follow the machine builder's safety procedures and lockout/tagout where hardware work is required.

Common Causes

  • Setting AN_TIMER_Nr of section [DAT] in ITS.INI is incompatible with the setting in machine data 18710 $MN_MM_NUM_AN_TIMER

Troubleshooting Steps

  1. 1The value in general machine data 18710 $MN_MM_NUM_AN_TIMER must be at least "1".
  2. 2The value set for AN_TIMER_Nr of section [DAT] in ITS.INI must be higher than "0" and smaller than or equal to the value of general machine data 18710 $MN_MM_NUM_AN_TIMER.
  3. 3The following rule applies: 0 < AN_TIMER_Nr <= $MN_MM_NUM_AN_TIMER

Seeing Multiple Alarms?

Seeing another alarm with this one? Enter the code.

Get machine-aware diagnosis

AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.

Start free

Was this guide helpful?

Always verify with your machine manual or a certified technician before performing service procedures.