SINUMERIK alarm 12050 occurs when the control cannot locate a target block number or label during program execution of jump commands (GOTOB, GOTOF), subroutine calls, or block search operations. The control searches through the active program memory and triggers this alarm when reaching program boundaries without finding the specified destination.
Siemens SINUMERIKProgram/G-codeBasic5-15 minutes
12050
Siemens 12050 - Block DIN address not configured
Block DIN address not configured
The name of the DIN address (e.g. X, U, X1) is not defined in the control. In addition to the fixed DIN addresses, the control also has variable addresses. Refer to "Variable addresses" in the Programming Guide. The names of these addresses can be altered by machine data. e.g.: DIN identifier -> Configured identifier G01 -> LINE, G04 -> WAIT Control reaction: Correction block is reorganized. Interface signals are set. Alarm display.
Root Cause Summary
SINUMERIK alarm 12050 occurs when the control cannot locate a target block number or label during program execution of jump commands (GOTOB, GOTOF), subroutine calls, or block search operations. The control searches through the active program memory and triggers this alarm when reaching program boundaries without finding the specified destination.
Safety
Only qualified personnel should diagnose and clear control alarms; follow the machine builder's safety procedures and lockout/tagout where hardware work is required.
Causes and Fixes
1
Check Program Editor for Target Block
Open HMI → Program → Program Editor and search for the referenced block number or label using the Find function (Search softkey).
Use Ctrl+F in the program editor to quickly locate block numbers and labels
2
Verify Jump Command Syntax
Check the syntax of GOTOB/GOTOF commands ensuring proper format: GOTOB LABEL1 or GOTOF N100, and verify label definitions start with the label name followed by a colon.
Labels are case-sensitive in SINUMERIK - ensure exact match between call and definition
3
Correct Missing References
Add the missing block number or label definition at the appropriate location in the program, or correct the jump command to reference an existing target.
Always backup the original program before making modifications
1
Compare Program Length
Check HMI → Program → Program Manager and compare the program size with the original file to identify potential truncation during transfer.
Use the program statistics function to verify total number of blocks transferred
2
Verify Communication Settings
Check HMI → Commissioning → HMI → Data Transfer settings including baud rate, parity, and handshake parameters match the sending device configuration.
Use XON/XOFF handshaking for reliable program transfers on older SINUMERIK systems
3
Retransfer Complete Program
Delete the corrupted program from Program Manager and retransfer the complete file using verified communication settings or USB/CF card transfer.
Ensure program is not active in any channel before deletion
1
Check Subroutine Directory
Navigate to HMI → Program → Program Manager and verify the called subroutine exists in the correct directory (typically _N_SPF_DIR for standard subprograms).
Use the directory tree view to check all subdirectories for missing subroutines
2
Verify Program Name Syntax
Ensure subroutine calls use correct SINUMERIK naming convention (e.g., L95 for subprogram O95.SPF or CALL "SUBPROG1") and check for proper file extensions.
Standard subprograms use .SPF extension, workpiece programs use .MPF
3
Load Missing Subroutines
Transfer missing subroutine files to the appropriate directory or create placeholder subroutines with RET command if temporarily not needed.
Placeholder subroutines should contain proper parameter handling to avoid additional alarms
1
Check Block Search Input
Verify the block number entered in HMI → Machine → Block Search matches an existing N-number in the active program exactly.
Block search is case-sensitive and requires exact N-number format (e.g., N100, not n100)
2
Review Search Configuration
Check machine data MD11210 (SEARCH_RUN_MODE) and MD11200 (SEARCH_FUNCTION_MASK) to ensure block search functionality is properly enabled.
MD11210 bit settings control forward/backward search behavior and block type recognition
3
Reset Search Function
Cancel current block search using Reset key, then restart search with verified block number or use Program Pointer positioning instead.
Ensure machine is in safe position before initiating block search operations
1
Check Nesting Depth
Verify program nesting levels do not exceed SINUMERIK limits defined in MD11150 (MAX_CALL_DEPTH) - typically 8 levels for subroutines and 4 for program calls.
Use program structure analysis tools in the HMI to visualize call hierarchy
2
Validate Loop Constructs
Check FOR/ENDFOR, WHILE/ENDWHILE, and REPEAT/UNTIL loop structures for proper pairing and ensure all conditional jumps have valid exit conditions.
Use program syntax checker in HMI → Program → Program Editor → Check Program function
3
Simplify Program Structure
Break complex nested structures into separate subroutines or reduce nesting depth to stay within SINUMERIK system limitations.
Test simplified program structure thoroughly before production use
DIY Feasiblehigh confidence
Call a technician if:
·Program corruption persists after multiple transfer attempts
·Machine data parameters require modification
·Complex program restructuring needed
Prevention
Always verify program transfers using checksum comparison
Use consistent naming conventions for blocks and labels
Implement program validation procedures before production
Maintain backup copies of all programs and subroutines
Common Mistakes
Case sensitivity errors in label names
Forgetting file extensions in subroutine calls
Using block search with non-existent N-numbers
Incomplete program transfers due to communication timeouts