Siemens SINUMERIK codes
Siemens SINUMERIKProgram/G-codeBasic5-15 minutes

12050

Siemens 12050 - Block DIN address not configured

Block DIN address not configured

The name of the DIN address (e.g. X, U, X1) is not defined in the control. In addition to the fixed DIN addresses, the control also has variable addresses. Refer to "Variable addresses" in the Programming Guide. The names of these addresses can be altered by machine data. e.g.: DIN identifier -> Configured identifier G01 -> LINE, G04 -> WAIT Control reaction: Correction block is reorganized. Interface signals are set. Alarm display.

Root Cause Summary

SINUMERIK alarm 12050 occurs when the control cannot locate a target block number or label during program execution of jump commands (GOTOB, GOTOF), subroutine calls, or block search operations. The control searches through the active program memory and triggers this alarm when reaching program boundaries without finding the specified destination.

Safety

  • Only qualified personnel should diagnose and clear control alarms; follow the machine builder's safety procedures and lockout/tagout where hardware work is required.

Causes and Fixes

  1. 1

    Check Program Editor for Target Block

    Open HMI → Program → Program Editor and search for the referenced block number or label using the Find function (Search softkey).

    Use Ctrl+F in the program editor to quickly locate block numbers and labels

  2. 2

    Verify Jump Command Syntax

    Check the syntax of GOTOB/GOTOF commands ensuring proper format: GOTOB LABEL1 or GOTOF N100, and verify label definitions start with the label name followed by a colon.

    Labels are case-sensitive in SINUMERIK - ensure exact match between call and definition

  3. 3

    Correct Missing References

    Add the missing block number or label definition at the appropriate location in the program, or correct the jump command to reference an existing target.

    Always backup the original program before making modifications

DIY Feasiblehigh confidence

Call a technician if:

  • ·Program corruption persists after multiple transfer attempts
  • ·Machine data parameters require modification
  • ·Complex program restructuring needed

Prevention

  • Always verify program transfers using checksum comparison
  • Use consistent naming conventions for blocks and labels
  • Implement program validation procedures before production
  • Maintain backup copies of all programs and subroutines

Common Mistakes

  • Case sensitivity errors in label names
  • Forgetting file extensions in subroutine calls
  • Using block search with non-existent N-numbers
  • Incomplete program transfers due to communication timeouts

Related Alarms

Seeing Multiple Alarms?

Seeing another alarm with this one? Enter the code.

Get machine-aware diagnosis

AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.

Start free

Was this guide helpful?

Always verify with your machine manual or a certified technician before performing service procedures.