120400

Siemens 120400 - The settings for the acyclic links with the drive devices are not yet effective.

The settings for the acyclic links with the drive devices are not yet effective.

Control reaction: Alarm display.

Root Cause Summary

SIEMENS alarm 120400 occurs when the integrated PLC transitions from RUN to STOP mode, halting execution of the cyclic user program OB1 and all PLC-controlled machine functions. This typically results from PLC program errors, hardware faults, or deliberate stops via HMI or programming device.

Safety

  • Drive/power/encoder circuit: hazardous voltages may remain in the DC link after power-off. Lock out / tag out, wait for discharge per the drive documentation, and use qualified personnel only.

Causes and Fixes

  1. 1

    Access PLC Diagnostics

    Navigate to HMI → Diagnostics → PLC → Status to view current PLC state and error buffer.

    Check timestamp of last error to correlate with machine events

  2. 2

    Analyze Error Buffer

    Review PLC error buffer for specific fault codes. Look for OB121 (programming errors) or OB122 (I/O access errors) entries.

    Do not clear error buffer until root cause is identified

  3. 3

    Check Program Logic

    Use STEP 7 or TIA Portal to examine the PLC program around the fault address. Verify data types, array bounds, and mathematical operations.

    Enable program monitoring to trace execution path leading to error

  4. 4

    Restart PLC

    After correcting program logic, set PLC to RUN mode via HMI → Machine → PLC or programming device.

    Ensure machine is in safe state before restarting PLC

DIY Feasiblehigh confidence

Call a technician if:

  • ·Hardware module replacement required
  • ·Complex PLC program debugging needed
  • ·Electrical power system modifications required

Prevention

  • Regular backup battery replacement every 2-3 years
  • Implement UPS for stable power supply
  • Regular PLC program backup and version control
  • Periodic I/O module health monitoring

Common Mistakes

  • Restarting PLC without identifying root cause
  • Ignoring hardware diagnostics
  • Not checking external stop signals
  • Clearing error buffer before analysis