Siemens SINUMERIK codes
Siemens SINUMERIKServo/AxisIntermediate30-60 minutes

10950

Siemens 10950 - Calculation of arc length function too inaccurate

Calculation of arc length function too inaccurate

The calculation of the arc length function could not be performed to the required accuracy Control reaction: Alarm display. Warning display.

Safety

  • Only qualified personnel should diagnose and clear control alarms; follow the machine builder's safety procedures and lockout/tagout where hardware work is required.

Common Causes

  • The calculation of the arc length function could not be performed to the required accuracy

Troubleshooting Steps

  1. 1The calculation of the arc length function could not be performed to the required accuracy during active polynomial interpolation.
  2. 2Either increase MD20262 $MC_SPLINE_FEED_PRECISION or reserve more memory for the representation of the arc length polynomials.
  3. 3MD28540 $MC_MM_ARCLENGTH_SEGMENTS defines how many polynomial segments can be used per block in order to approximate the arc length function.
  4. 4Clear alarm with NC START or RESET key and continue the program

Seeing Multiple Alarms?

Seeing another alarm with this one? Enter the code.

Get machine-aware diagnosis

AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.

Start free

Was this guide helpful?

Always verify with your machine manual or a certified technician before performing service procedures.