Siemens 10750 - Block tool radius compensation activated without tool number

Block tool radius compensation activated without tool number

Siemens SINUMERIK alarm 10750: Block tool radius compensation activated without tool number. Detailed remedy is being verified against the current Siemens diagnostics manual.

Root Cause Summary

SINUMERIK alarm 10750 triggers when the drive current exceeds the configured maximum limit defined in MD32110 (MAX_CURRENT_LIMIT). This typically occurs due to mechanical binding, excessive cutting loads, or drive parameter misconfiguration causing the servo amplifier to draw excessive current while attempting to maintain position.

Safety

  • Only qualified personnel should diagnose and clear control alarms; follow the machine builder's safety procedures and lockout/tagout where hardware work is required.

Causes and Fixes

  1. 1

    Check Axis Movement

    Navigate to Machine > Manual Machine > JOG mode and attempt slow manual movement of the affected axis at 1% feedrate override.

    Ensure machine is in safe position before manual movement

  2. 2

    Inspect Mechanical Components

    Check ballscrews, linear guides, and coupling connections for debris, damage, or binding. Verify proper lubrication levels.

    Listen for unusual grinding or clicking sounds during movement

  3. 3

    Verify Travel Limits

    Check MD36100 (POS_LIMIT_PLUS) and MD36110 (POS_LIMIT_MINUS) against actual machine position in Diagnostics > Drive > Actual Values.

    Compare machine coordinates with workpiece coordinate offsets

DIY Feasiblemedium confidence

Call a technician if:

  • ·Multiple drive alarms present
  • ·Motor insulation failure detected
  • ·Drive hardware fault suspected
  • ·Encoder replacement required

Prevention

  • Regular mechanical maintenance and lubrication
  • Monitor cutting parameters and tool wear
  • Periodic drive optimization
  • Keep encoder connections clean and secure

Common Mistakes

  • Ignoring mechanical binding symptoms
  • Setting current limits too low
  • Not checking for multiple related alarms
  • Adjusting servo gains without documentation

Related Alarms

Seeing Multiple Alarms?

Seeing another alarm with this one? Enter the code.

Get machine-aware diagnosis

AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.

Start free

Was this guide helpful?

Always verify with your machine manual or a certified technician before performing service procedures.