Siemens SINUMERIK codes
Siemens SINUMERIKProgram/G-codeIntermediate30-120 minutes

10202

Siemens 10202 - [up to SW 3.x] Channel NC start not possible

[up to SW 3.x] Channel NC start not possible

NC start is not accepted because, e.g. - REORG is still active - Delete distance-to-go is still active - The system is waiting for another channel Control reaction: Alarm display.

Root Cause Summary

Alarm 10202 occurs when the NC program cannot be started in the specified channel due to active inhibiting conditions. This is typically caused by program selection errors, active alarms blocking execution, or the control being in an operational state that prevents NC start (such as an active program already running or critical safety/mode conditions).

Safety

  • Only qualified personnel should diagnose and clear control alarms; follow the machine builder's safety procedures and lockout/tagout where hardware work is required.

Causes and Fixes

  1. 1

    Check the HMI program manager to verify a valid NC program is selected in the affected channel.

  2. 2

    Verify the selected program can be opened and displayed without errors. Check for file corruption or incomplete program transfer.

  3. 3

    Review any preceding alarms or error messages that may indicate program syntax errors or loading failures.

  4. 4

    Attempt to reload the program from a backup or re-transfer from CAM system if file integrity is suspect.

Service Recommended confidence

Seeing Multiple Alarms?

Seeing another alarm with this one? Enter the code.

Get machine-aware diagnosis

AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.

Start free

Was this guide helpful?

Always verify with your machine manual or a certified technician before performing service procedures.