Siemens SINUMERIK codes
Siemens SINUMERIKProgram/G-codeIntermediate30-120 minutes

102002

Siemens 840D 102002 - Write error on disk

Write error on disk

Siemens SINUMERIK alarm 102002: Write error on disk. This alarm indicates an error condition in the NC program or control configuration that must be resolved before the operation can continue.

Root Cause Summary

Alarm 102002 indicates the SINUMERIK control cannot write data to the hard disk or CompactFlash storage media. This typically occurs due to disk full conditions, write-protected media, file system corruption, or physical storage device failure preventing the system from saving NC programs, parameters, or system files.

Safety

  • Refer to Siemens documentation
  • Ensure qualified technician performs repairs

Causes and Fixes

  1. 1

    Check available disk space via HMI: Service > System Data > Hard Disk. Review capacity and free space percentage.

  2. 2

    Delete obsolete NC programs from Program Manager (/_N_WKS_DIR or user directories) or remove old archive files from /_N_ARC_DIR.

    Always backup critical NC programs to external media before deletion

  3. 3

    Clear system log files if storage is critical: Navigate to /_N_LOG_DIR and archive/delete old alarm and trace logs.

    Document current alarms before clearing logs for service history

  4. 4

    Perform system archive to external USB/network location, then remove archive from internal storage to free space.

Service Recommended confidence

Seeing Multiple Alarms?

Seeing another alarm with this one? Enter the code.

Get machine-aware diagnosis

AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.

Start free

Was this guide helpful?

Always verify with your machine manual or a certified technician before performing service procedures.