Siemens 840D 102002 - Write error on disk
Alarm 102002 indicates the SINUMERIK control cannot write data to the hard disk or CompactFlash storage media. This typically occurs due to disk full conditions, write-protected media, file system corruption, or physical storage device failure preventing the system from saving NC programs, parameters, or system files.
Siemens 840D 102002 - Write error on disk
Write error on disk
Siemens SINUMERIK alarm 102002: Write error on disk. This alarm indicates an error condition in the NC program or control configuration that must be resolved before the operation can continue.
Root Cause Summary
Alarm 102002 indicates the SINUMERIK control cannot write data to the hard disk or CompactFlash storage media. This typically occurs due to disk full conditions, write-protected media, file system corruption, or physical storage device failure preventing the system from saving NC programs, parameters, or system files.
Safety
Causes and Fixes
Check available disk space via HMI: Service > System Data > Hard Disk. Review capacity and free space percentage.
Delete obsolete NC programs from Program Manager (/_N_WKS_DIR or user directories) or remove old archive files from /_N_ARC_DIR.
Always backup critical NC programs to external media before deletion
Clear system log files if storage is critical: Navigate to /_N_LOG_DIR and archive/delete old alarm and trace logs.
Document current alarms before clearing logs for service history
Perform system archive to external USB/network location, then remove archive from internal storage to free space.