Siemens 840D 102009 - RS232C stop accepted - please wait !
This is an informational message, not a fault alarm. It indicates that a stop command has been issued during an active RS232C serial data transfer, and the control is properly terminating the communication session. The system requires time to safely close the serial interface connection before proceeding.
Siemens 840D 102009 - RS232C stop accepted - please wait !
RS232C stop accepted - please wait !
Siemens SINUMERIK message 102009: RS232C stop accepted - please wait!. This is an operator information message from the SINUMERIK control. Note the complete message text as it may contain important parameter values.
Root Cause Summary
This is an informational message, not a fault alarm. It indicates that a stop command has been issued during an active RS232C serial data transfer, and the control is properly terminating the communication session. The system requires time to safely close the serial interface connection before proceeding.
Safety
Causes and Fixes
Wait for the message to clear automatically - this typically takes 2-10 seconds depending on buffer size and transmission state.
Do not power cycle or force-reset the control while this message is displayed - allow proper communication closure.
Forcing a reset during this phase may corrupt the serial interface buffer or require V.24 interface reinitialization.
Once message clears, verify RS232C cable is properly seated if you need to restart the transfer immediately.
If resuming DNC operation, reinitiate the transfer from the beginning - partial transfers cannot be resumed on 840D systems.