Siemens SINUMERIK codes
Siemens SINUMERIKCommunicationIntermediate30-120 minutes

100911

Siemens 840D 100911 - Remote diagnostics: Error 01 -int4f_func(ACCEPT)-

Remote diagnostics: Error 01 -int4f_func(ACCEPT)-

Siemens SINUMERIK alarm 100911: Remote diagnostics: Error 01 -int4f_func(ACCEPT)-. This alarm indicates an error condition in the NC program or control configuration that must be resolved before the operation can continue.

Root Cause Summary

Alarm 100911 indicates a communication failure in the remote diagnostics system, specifically an internal error with the ACCEPT function for socket connections. This occurs when the control cannot establish or maintain a remote diagnostic TCP/IP connection, typically due to network configuration issues, firewall blocking, or corrupted communication parameters in the system software.

Safety

  • Refer to Siemens documentation
  • Ensure qualified technician performs repairs

Causes and Fixes

  1. 1

    Check NCU network settings via HMI: Startup > Network Configuration. Verify IP address, subnet mask, and gateway are correct and match your network infrastructure.

  2. 2

    Verify Windows firewall settings on PCU/TCU if using integrated systems. Ensure ports 102, 443, and any custom remote service ports are open for inbound connections.

    Changing firewall settings may expose the system to security risks. Consult IT security policies before modification.

  3. 3

    Check network switch/router configuration between NCU and remote diagnostics workstation. Verify VLAN settings and port forwarding rules allow diagnostic traffic.

  4. 4

    Test basic network connectivity using PING command from service laptop to NCU IP address. If ping fails, resolve network layer issues before proceeding.

Service Recommended confidence

Seeing Multiple Alarms?

Seeing another alarm with this one? Enter the code.

Get machine-aware diagnosis

AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.

Start free

Was this guide helpful?

Always verify with your machine manual or a certified technician before performing service procedures.