Siemens 840D 100911 - Remote diagnostics: Error 01 -int4f_func(ACCEPT)-
Alarm 100911 indicates a communication failure in the remote diagnostics system, specifically an internal error with the ACCEPT function for socket connections. This occurs when the control cannot establish or maintain a remote diagnostic TCP/IP connection, typically due to network configuration issues, firewall blocking, or corrupted communication parameters in the system software.
Siemens 840D 100911 - Remote diagnostics: Error 01 -int4f_func(ACCEPT)-
Remote diagnostics: Error 01 -int4f_func(ACCEPT)-
Siemens SINUMERIK alarm 100911: Remote diagnostics: Error 01 -int4f_func(ACCEPT)-. This alarm indicates an error condition in the NC program or control configuration that must be resolved before the operation can continue.
Root Cause Summary
Alarm 100911 indicates a communication failure in the remote diagnostics system, specifically an internal error with the ACCEPT function for socket connections. This occurs when the control cannot establish or maintain a remote diagnostic TCP/IP connection, typically due to network configuration issues, firewall blocking, or corrupted communication parameters in the system software.
Safety
Causes and Fixes
Check NCU network settings via HMI: Startup > Network Configuration. Verify IP address, subnet mask, and gateway are correct and match your network infrastructure.
Verify Windows firewall settings on PCU/TCU if using integrated systems. Ensure ports 102, 443, and any custom remote service ports are open for inbound connections.
Changing firewall settings may expose the system to security risks. Consult IT security policies before modification.
Check network switch/router configuration between NCU and remote diagnostics workstation. Verify VLAN settings and port forwarding rules allow diagnostic traffic.
Test basic network connectivity using PING command from service laptop to NCU IP address. If ping fails, resolve network layer issues before proceeding.