Siemens 840D 100910 - Remote diagnostics: Error 00 -int4f_func(CREATE_SRV)-
Alarm 100910 indicates a failure in the remote diagnostics service during the CREATE_SRV function initialization. This is typically related to communication service initialization failures between the NCU and external diagnostic tools, often caused by network configuration issues, firewall blocking, or corrupted VPN/remote access service parameters.
Siemens 840D 100910 - Remote diagnostics: Error 00 -int4f_func(CREATE_SRV)-
Remote diagnostics: Error 00 -int4f_func(CREATE_SRV)-
Siemens SINUMERIK alarm 100910: Remote diagnostics: Error 00 -int4f_func(CREATE_SRV)-. This alarm indicates an error condition in the NC program or control configuration that must be resolved before the operation can continue.
Root Cause Summary
Alarm 100910 indicates a failure in the remote diagnostics service during the CREATE_SRV function initialization. This is typically related to communication service initialization failures between the NCU and external diagnostic tools, often caused by network configuration issues, firewall blocking, or corrupted VPN/remote access service parameters.
Safety
Causes and Fixes
Verify NCU network settings: Check IP address, subnet mask, and gateway configuration in HMI under Commissioning > Network settings. Ensure settings match your network infrastructure.
Verify that TCP ports 102, 443, and 5900-5910 are open and not blocked by Windows Firewall or corporate firewall on both NCU and connecting PC.
Coordinate with IT department before modifying firewall rules on production networks.
Test network connectivity using PING command from HMI diagnostics to the remote diagnostic PC. Check for packet loss or timeout errors.
Restart the NCU communication services via HMI: Go to Commissioning > System > Control > select 'Restart Communication'. Wait 2-3 minutes for services to reinitialize.
This will temporarily interrupt all network-based communications including HMI connections.