Okuma OSP Alarm B 2894 - Spindle lubricant controller error
The spindle lubrication system is not confirming healthy operation. Either the lubricant controller's alarm/OK signal (input I.025C) stayed off for more than one second, or the oil flow confirmation input stayed off, meaning the spindle may be running without verified lubrication.
Okuma OSP Alarm B 2894 - Spindle lubricant controller error
Spindle lubricant controller error
The spindle lubrication system is not confirming healthy operation. Either the lubricant controller's alarm/OK signal (input I.025C) stayed off for more than one second, or the oil flow confirmation input stayed off, meaning the spindle may be running without verified lubrication.