KUKA Robot KRC0052 - K1 CONTACT FAIL TO OPEN <KPS number>

K1 CONTACT FAIL TO OPEN <KPS number>

The K1 safety contactor has failed to open during a safety circuit check, indicating the contacts are welded or stuck in the closed position. This prevents proper disconnection of power during emergency stops or safety-related shutdowns. The alarm includes the KPS (KUKA Power Supply) number to identify which specific power module or safety circuit is affected.

Common Causes

  • K1 contactor contacts welded due to electrical arcing or high inrush current
  • Contamination or oxidation on contactor contacts preventing proper separation
  • Mechanical jamming of the contactor plunger or movable contact arm
  • Insufficient contact pressure or worn contact springs in the K1 relay
  • Voltage surge or transient spike causing contact fusion during switching

Troubleshooting Steps

  1. 1Verify the alarm persists by performing a full system power cycle and safety system reset through the teach pendant
  2. 2Inspect the K1 contactor physically for visible signs of pitting, burning, or welding marks on the contact surfaces
  3. 3Check the coil voltage and resistance of the K1 contactor using a multimeter to ensure proper electrical operation
  4. 4Examine the mechanical linkage and plunger movement of the K1 contactor for sticking or binding conditions
  5. 5Test the safety circuit continuity and switching response using KRC diagnostics or KPS-specific testing procedures
  6. 6Replace the K1 contactor assembly if welding is confirmed, as contacts cannot be reliably restored once fused