HEIDENHAIN 330-0015 - CC inverter for axis RDY=0
The inverter power section for this axis is not achieving ready state, which prevents the control from enabling the drive. This is typically caused by missing DC bus voltage, a hardware fault within the inverter module, or a communication breakdown between the digital controller and power stage. The RDY=0 condition is a protective mechanism preventing operation with a non-functional power section.
HEIDENHAIN 330-0015 - CC inverter for axis RDY=0
CC inverter for axis RDY=0
The power module could not be switched to ready condition. This may be due to safety relay issues, wiring faults, or defective power modules.
Root Cause Summary
The inverter power section for this axis is not achieving ready state, which prevents the control from enabling the drive. This is typically caused by missing DC bus voltage, a hardware fault within the inverter module, or a communication breakdown between the digital controller and power stage. The RDY=0 condition is a protective mechanism preventing operation with a non-functional power section.
Safety
Causes and Fixes
Check power supply unit status
Inspect the main power supply unit LED indicators. Green LED should be steady, indicating proper DC bus voltage generation. Check for fault LEDs or error codes on the PSU module.
Work must be performed by qualified electrical personnel. Lethal voltages present even when machine is powered off due to DC bus capacitors.
Measure DC bus voltage
Using appropriate high-voltage test equipment, measure DC bus voltage at the inverter input terminals. Standard specification is 560-600VDC for 400VAC input systems. Voltage below 500VDC will typically prevent inverter ready status.
High voltage measurement requires proper PPE and qualified personnel. Ensure proper isolation and test equipment rated for DC bus voltages.
Check DC bus fuses and contactors
Verify that all DC bus fuses are intact and DC bus contactors are closing properly. Check for signs of arcing or thermal damage at connection points. Measure voltage on both sides of contactors when closed.
On multi-axis systems, compare DC bus voltage across all inverter modules. If only one axis shows low/no voltage, suspect local connection or distribution issue rather than main PSU failure.
Inspect inverter power connections
Check all DC bus bar connections, screw terminals, and press-fit contacts at the inverter module. Loose connections can cause voltage drops or intermittent RDY failures. Torque all connections to specification.
Thermal cycling can loosen power connections over time. Check for discoloration around terminals indicating overheating from loose connections.
Call a technician if:
Prevention
Common Mistakes