Heidenhain codes
HeidenhainServo/AxisIntermediate30-120 minutes

320-0063

HEIDENHAIN 320-0063 - Invalid configuration for PLC log files

Invalid configuration for PLC log files

A PLC configuration or communication error has been detected. This affects the interaction between the control and the PLC system.

Root Cause Summary

HEIDENHAIN alarm 320-0063 occurs when the PLC logging configuration parameters in CfgPlcLogging are corrupted, contain invalid values, or reference non-existent file paths. This typically happens after system updates, configuration file corruption, or incorrect manual parameter modifications in the TNC control.

Safety

  • Refer to Heidenhain service manual
  • Ensure qualified technician performs repairs

Causes and Fixes

  1. 1

    Access system configuration

    Press MOD key, select 'System' → 'Configuration' → 'Machine Parameters' → 'CfgPlcLogging' to view current logging configuration.

    Always backup the original configuration before making changes

  2. 2

    Verify configuration syntax

    Check CfgPlcLogging entries for proper XML syntax, valid file paths, and correct parameter formatting in the configuration display.

    Invalid syntax can cause system instability

  3. 3

    Restore default configuration

    Navigate to 'System' → 'Service' → 'Configuration Reset' and select 'PLC Logging' to restore factory defaults for CfgPlcLogging parameters.

  4. 4

    Restart PLC system

    Execute PLC restart via 'PLC' → 'Operating Mode' → 'Stop/Start' to reinitialize logging with corrected configuration.

DIY Feasiblehigh confidence

Call a technician if:

  • ·Configuration file corruption persists after multiple restore attempts
  • ·Network path authentication issues
  • ·System crashes during PLC restart

Prevention

  • Backup CfgPlcLogging before modifications
  • Validate file paths before configuration changes
  • Monitor log file sizes regularly
  • Document all configuration changes

Common Mistakes

  • Using Windows file paths instead of TNC format
  • Exceeding system log file limits
  • Not restarting PLC after configuration changes
  • Ignoring file permission requirements