Heidenhain Controller
Communication · Intermediate · 30-120 minutes
HEIDENHAIN 235-00A1 - Falsches Modul in HSCI-Gerät
HEIDENHAIN alarm 235-00A1 occurs when the physical HSCI module configuration doesn't match the projected configuration in the TNC control. This mismatch between expected and actual hardware modules at specific HSCI addresses prevents proper system initialization.
HEIDENHAIN 235-00A1 - Falsches Modul in HSCI-Gerät
Falsches Modul in HSCI-Gerät
In an HSCI device, modules do not match the configuration. The installed modules differ from what was projected.
Root Cause Summary
HEIDENHAIN alarm 235-00A1 occurs when the physical HSCI module configuration doesn't match the projected configuration in the TNC control. This mismatch between expected and actual hardware modules at specific HSCI addresses prevents proper system initialization.
Safety
Causes and Fixes
Access MOD Parameters
Navigate to Setup → General → Machine Parameters → MOD and check the HSCI configuration parameters for the reported address %3.
Document current MOD settings before making changes for easy rollback.
Verify Physical Module Type
Check the actual module type installed at HSCI slot position matching address %3 and compare with the alarm's Hardware: %2 information.
Power down the control before inspecting HSCI modules to prevent damage.
Correct MOD Configuration
Update the relevant MOD parameters to match the physical hardware configuration, then perform a control restart to reinitialize the HSCI system.
Call a technician if:
Prevention
Common Mistakes
Seeing Multiple Alarms?
Seeing another alarm with this one? Enter the code.
AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.
Start freeWas this guide helpful?
Always verify with your machine manual or a certified technician before performing service procedures.