HEIDENHAIN 235-009E - Non-configured device in the HSCI chain

Non-configured device in the HSCI chain

Extra hardware exists in the HSCI chain without matching configuration entries. Vague data prevents pinpointing exactly which devices are unconfigured.

Root Cause Summary

HEIDENHAIN alarm 235-009E occurs when the TNC control detects a physical HSCI device that is not defined in the machine configuration parameters. This mismatch between the configured HSCI chain topology and the actual hardware prevents proper communication initialization.

Safety

  • Refer to Heidenhain service manual
  • Ensure qualified technician performs repairs

Causes and Fixes

  1. 1

    Access HSCI Configuration Parameters

    Press MOD key, select 'Machine Parameters', navigate to MP7200 'HSCI Configuration' section.

    Document current MP7200 values before making changes for rollback purposes.

  2. 2

    Compare Configuration to Hardware

    Check MP7200.0 through MP7200.15 entries against physical HSCI devices. Note HSCI addresses and device types from the alarm message variables %1 and %2.

    Incorrect HSCI configuration can disable critical machine functions.

  3. 3

    Update Missing Device Entries

    Add missing device entries to appropriate MP7200.x parameters using correct device type codes and HSCI addresses shown in alarm details.

  4. 4

    Restart Control System

    Perform complete TNC restart (Ctrl+Alt+Del or power cycle) to reinitialize HSCI chain with updated configuration.

DIY Feasiblehigh confidence

Call a technician if:

  • ·MP7200 configuration changes don't resolve alarm
  • ·Physical HSCI hardware damage suspected
  • ·Multiple HSCI devices fail simultaneously

Prevention

  • Document all HSCI configuration changes in machine logbook
  • Verify MP7200 parameters after any hardware modifications
  • Perform HSCI diagnostics during preventive maintenance

Common Mistakes

  • Forgetting to restart TNC after MP7200 changes
  • Configuring HSCI address 0 (addresses start at 1)
  • Not updating MP128 hardware options when adding HSCI devices