HEIDENHAIN 235-0099 - Projektiertes Gerät nicht im HSCI-Strang

Projektiertes Gerät nicht im HSCI-Strang

Auf dem HSCI-Strang fehlen projektierte Geräte. Die Konfiguration stimmt nicht mit der tatsächlichen Hardware überein.

Root Cause Summary

HEIDENHAIN alarm 235-0099 indicates that a configured device in the HSCI (High Speed Communication Interface) chain is not physically present or responding. This occurs when the TNC control expects to communicate with a specific device based on the machine configuration but cannot establish contact with it.

Safety

  • Refer to Heidenhain service manual
  • Ensure qualified technician performs repairs

Causes and Fixes

  1. 1

    Access Machine Parameters

    Press MOD key, select 'Machine Parameters' and navigate to MP7300-MP7399 (HSCI configuration parameters).

    Always backup current parameters before making changes using the parameter export function.

  2. 2

    Check Hardware Configuration

    Review MP7310 (HSCI device configuration) and MP7320 series parameters to verify configured devices match actual hardware installation.

    Incorrect parameter changes can disable machine functionality.

  3. 3

    Verify Option Switches

    Check software option switches in MOD > Software Options to ensure hardware expansion options match the physical configuration.

    Document all option switch settings before modifications for easy rollback.

  4. 4

    Restart Control

    Perform a complete power cycle of the TNC control to reinitialize HSCI communication with corrected parameters.

DIY Feasiblehigh confidence

Call a technician if:

  • ·HSCI interface card suspected faulty
  • ·Multiple parameter changes required
  • ·Physical device replacement needed

Prevention

  • Regular HSCI cable inspection
  • Maintain proper cable routing away from interference sources
  • Document all HSCI device addresses and configurations
  • Perform periodic connection torque checks

Common Mistakes

  • Modifying parameters without backup
  • Incorrect termination resistor installation
  • Mixing HSCI cable types
  • Not following proper ESD procedures during connection work