Heidenhain codes
HeidenhainServo/AxisIntermediate30-120 minutes

231-C480

HEIDENHAIN 231-C480 - C480 V/Hz control mode with encoder

C480 V/Hz control mode with encoder

The motor table selects volts-per-hertz control (STR = 0) while a motor encoder is also configured (SYS not 0). These settings contradict each other and must be corrected.

Root Cause Summary

HEIDENHAIN alarm 231-C480 occurs when the motor table has conflicting control mode settings - specifically when V/Hz control mode is selected (STR parameter = 0) but an encoder system is also configured (SYS parameter ≠ 0). This creates an incompatible configuration since V/Hz control operates open-loop without encoder feedback.

Safety

  • Refer to Heidenhain service manual
  • Ensure qualified technician performs repairs

Causes and Fixes

  1. 1

    Access motor configuration table

    Navigate to Setup → Machine Parameters → Axes/Spindles → Motor Table and locate the affected motor entry.

    Document current settings before making changes for rollback purposes

  2. 2

    Check STR parameter value

    Verify the STR parameter shows 0 (V/Hz mode). This should typically be 1 for servo control or 2 for vector control with encoder feedback.

    Changing control modes requires understanding of motor and drive characteristics

  3. 3

    Correct STR parameter setting

    Change STR parameter to appropriate value: 1 for standard servo control or 2 for vector control, matching your encoder configuration.

    Consult drive documentation to determine optimal control mode for your specific motor/encoder combination

  4. 4

    Validate configuration and restart

    Save parameters, perform PLC restart, and verify alarm clears during system initialization.

DIY Feasiblehigh confidence

Call a technician if:

  • ·Parameter changes don't resolve alarm
  • ·Uncertainty about motor control requirements
  • ·Multiple related alarms persist

Prevention

  • Always validate motor table consistency after parameter changes
  • Use motor-specific templates rather than copying entries
  • Maintain parameter backups before configuration changes
  • Document motor and encoder specifications for reference

Common Mistakes

  • Copying motor parameters between different motor types
  • Assuming all motors use same control mode
  • Not verifying physical hardware matches parameter settings
  • Changing individual parameters without considering system compatibility