Heidenhain Controller
Communication · Intermediate · 30-120 minutes
HEIDENHAIN 231-C027 - C027 HSCI message is missing
HEIDENHAIN alarm 231-C027 occurs when the HSCI (High Speed Communication Interface) low-priority message communication fails between the TNC control and connected HSCI stations. This typically indicates a breakdown in the cyclic data exchange or corrupted message lists in the Motion Controller.
HEIDENHAIN 231-C027 - C027 HSCI message is missing
C027 HSCI message is missing
This TNC 640 error indicates a communication failure between control components. The HSCI data exchange has been interrupted or corrupted.
Root Cause Summary
HEIDENHAIN alarm 231-C027 occurs when the HSCI (High Speed Communication Interface) low-priority message communication fails between the TNC control and connected HSCI stations. This typically indicates a breakdown in the cyclic data exchange or corrupted message lists in the Motion Controller.
Safety
Causes and Fixes
Check HSCI cable connections
Verify all HSCI cables are securely connected at both TNC control and HSCI station ends. Check X116/X117 connectors on CC/MC unit.
Power down system before checking connections to prevent damage
Inspect cable integrity
Examine HSCI cables for physical damage, kinks, or wear. Test cable continuity with multimeter if damage suspected.
HSCI cables are sensitive to EMI - ensure proper shielding and routing away from power cables
Test with known good cable
Replace suspected HSCI cable with verified working cable to isolate connection issues.
Keep spare HSCI cables in service kit - they're common failure points
Call a technician if: