Heidenhain codes
HeidenhainCommunicationIntermediate30-120 minutes

231-C006

HEIDENHAIN 231-C006 - C006 I-CTRL communication: TIME

C006 I-CTRL communication: TIME

This TNC 640 error indicates a communication failure between control components. The HSCI data exchange has been interrupted or corrupted.

Root Cause Summary

HEIDENHAIN alarm 231-C006 indicates a communication timeout between the speed controller and current controller within the drive system. This typically occurs when the internal control loop communication exceeds the predefined timeout threshold, often due to hardware failures, cable issues, or drive module malfunctions.

Safety

  • Refer to Heidenhain service manual
  • Ensure qualified technician performs repairs

Causes and Fixes

  1. 1

    Check drive status LEDs

    Examine the drive module status indicators on the MC main computer unit for red error LEDs or abnormal blinking patterns.

    Ensure machine is in emergency stop before inspecting drive modules

  2. 2

    Access drive diagnostics

    Navigate to MOD function -> DIAGNOSIS -> DRIVE STATUS to check individual axis drive conditions and error registers.

    Look for additional error codes in the drive status that may indicate specific hardware failures

  3. 3

    Perform drive reset sequence

    Execute CTRL+ALT+DEL followed by machine parameter reset via MP7300 (RESET_DRIVES) to clear potential software locks.

    Document current machine parameters before reset

  4. 4

    Verify drive module seating

    Power down completely and reseat drive modules in the MC unit, ensuring proper connector engagement and cooling fan operation.

DIY Feasiblemedium confidence

Call a technician if:

  • ·Drive module replacement required
  • ·Parameter corruption with no backup available
  • ·Multiple simultaneous drive failures

Prevention

  • Regular encoder cable inspection during PM
  • Maintain stable power supply voltages
  • Keep drive modules clean and properly cooled
  • Backup machine parameters monthly

Common Mistakes

  • Ignoring power supply voltage variations
  • Replacing drives without checking cables first
  • Modifying timing parameters without understanding relationships
  • Not checking for EMI sources during troubleshooting

Seeing Multiple Alarms?

Seeing another alarm with this one? Enter the code.

Get machine-aware diagnosis

AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.

Start free

Was this guide helpful?

Always verify with your machine manual or a certified technician before performing service procedures.