Heidenhain codes
HeidenhainPower SupplyIntermediate30-120 minutes

231-B900

HEIDENHAIN 231-B900 - B900 CC supply voltage

B900 CC supply voltage

This TNC 640 error indicates a problem with the power supply system. The control has detected abnormal conditions in the mains power or DC-link voltage.

Root Cause Summary

HEIDENHAIN alarm 231-B900 indicates supply voltage issues on the CC board, specifically with the +5V, +15V, or -15V rails being outside acceptable operating ranges. This servo alarm typically results from power supply unit failures, excessive encoder loading on the +5V rail, or CC board component degradation.

Safety

  • Refer to Heidenhain service manual
  • Ensure qualified technician performs repairs

Causes and Fixes

  1. 1

    Check PSU Status LEDs

    Examine the power supply unit status indicators on the main cabinet. Green LEDs should be solid, red indicates fault conditions.

    Ensure main power is locked out before opening electrical cabinet

  2. 2

    Measure DC Voltages

    Using a multimeter, verify +15VDC and -15VDC rails at the PSU output terminals. Acceptable range is typically ±14.25V to ±15.75V.

    Check voltages under load - some PSUs fail only when loaded

  3. 3

    Inspect PSU Connections

    Verify all DC output connections from PSU to CC board are tight and show no signs of arcing or overheating.

    Loose connections can cause voltage fluctuations and intermittent alarms

  4. 4

    Replace PSU if Faulty

    If voltages are out of specification, replace the power supply unit with Heidenhain-approved equivalent and clear alarm via MOD function.

    Always verify part numbers match exactly - voltage ratings are critical

DIY Feasiblehigh confidence

Call a technician if:

  • ·CC board replacement required
  • ·Multiple voltage rails affected simultaneously
  • ·Alarm persists after PSU replacement

Prevention

  • Regular PSU voltage monitoring
  • Annual encoder current load verification
  • Maintain clean electrical cabinet environment
  • Implement preventive CC board replacement every 8-10 years

Common Mistakes

  • Ignoring encoder current specifications
  • Not checking voltage under load conditions
  • Replacing CC board without addressing root cause
  • Inadequate ESD protection during board handling

Related Alarms

Seeing Multiple Alarms?

Seeing another alarm with this one? Enter the code.

Get machine-aware diagnosis

AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.

Start free

Was this guide helpful?

Always verify with your machine manual or a certified technician before performing service procedures.