Heidenhain Controller
Parameter · Intermediate · 30-120 minutes
HEIDENHAIN 230-04ED - Parameters of current controller are not correct
HEIDENHAIN alarm 230-04ED occurs when the current controller parameters in CfgCurrentControl are incorrectly mixed between legacy single-gain parameters and modern dual-axis gain parameters. The TNC system requires either the old iCtrlPropGain/iCtrlIntGain pair OR the new D/Q axis specific parameters, but not both simultaneously.
HEIDENHAIN 230-04ED - Parameters of current controller are not correct
Parameters of current controller are not correct
Current controller parameters are incorrectly configured. Mixed parameterization using both old and new parameter sets is not allowed.
Root Cause Summary
HEIDENHAIN alarm 230-04ED occurs when the current controller parameters in CfgCurrentControl are incorrectly mixed between legacy single-gain parameters and modern dual-axis gain parameters. The TNC system requires either the old iCtrlPropGain/iCtrlIntGain pair OR the new D/Q axis specific parameters, but not both simultaneously.
Safety
Causes and Fixes
Access Current Controller Configuration
Navigate to MOD function → Machine Parameters → CfgCurrentControl to examine current controller parameter settings.
Use Ctrl+F to quickly search for 'iCtrlProp' and 'iCtrlInt' parameters
Identify Parameter Conflict
Check if both legacy parameters (iCtrlPropGain, iCtrlIntGain) and D/Q parameters (iCtrlPropGainD/Q, iCtrlIntGainD/Q) have non-zero values configured.
Document existing values before making changes for rollback purposes
Select Parameter Set
Choose either legacy single-gain parameters for older servo drives or D/Q axis parameters for modern vector-controlled drives based on your servo amplifier specifications.
Modern Heidenhain servo amplifiers typically require D/Q axis parameterization
Clear Conflicting Parameters
Set the unused parameter set to zero values and save the machine parameters with PGM MGT → Save Machine Parameters.
Incorrect current controller settings can cause servo instability or damage
Call a technician if:
Prevention
Common Mistakes
Related Alarms
Seeing Multiple Alarms?
Seeing another alarm with this one? Enter the code.
AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.
Start freeWas this guide helpful?
Always verify with your machine manual or a certified technician before performing service procedures.