Heidenhain codes
HeidenhainParameterIntermediate30-120 minutes

160-0123

HEIDENHAIN 160-0123 - Alias strobe of type not configured

Alias strobe of type not configured

An alias strobe command was issued, but the PLC configuration lacks the matching definition. Either the CfgPlcStrobeAlias object is missing or it was never added to the aliasStrobes list.

Root Cause Summary

The alarm is triggered when the control's internal software attempts to use a specific type of alias strobe for data synchronization, but that strobe type has not been declared or properly configured in the system configuration files. This typically results from incomplete configuration after hardware changes, software updates, or configuration file corruption.

Safety

  • Refer to Heidenhain service manual
  • Ensure qualified technician performs repairs

Causes and Fixes

  1. 1

    Access Configuration Files

    Enter MOD mode (key switch to position 2), select 'System Files', navigate to TNC:\system\ and open SIK.SYS for review. Look for ALIAS_STROBE sections and note configured types.

    Always create a backup copy of SIK.SYS before making any modifications - store it on external USB media with date stamp.

  2. 2

    Identify Missing Strobe Type

    Cross-reference the %1 parameter from the alarm message with existing ALIAS_STROBE entries in SIK.SYS. Check machine manufacturer documentation for required strobe type definitions for your specific hardware configuration.

    The %1 parameter typically indicates the strobe number or type - common values are 0-3 for different synchronization channels.

  3. 3

    Add Missing Configuration Entry

    If the strobe type is missing, add the appropriate ALIAS_STROBE definition to SIK.SYS using the exact syntax from machine documentation. Ensure proper formatting with correct module addresses and timing parameters.

    Incorrect strobe configuration can cause communication failures with drives or I/O modules. Only use parameters provided by machine manufacturer or Heidenhain technical support.

  4. 4

    Reload Configuration

    Save the modified SIK.SYS file, exit MOD mode, and perform a complete control reboot (power cycle) to ensure all configuration changes are loaded into active memory.

    Monitor the boot sequence on screen - configuration errors will typically display during initialization phase.

DIY Feasiblehigh confidence

Call a technician if:

  • ·Configuration backup restoration fails
  • ·Hardware compatibility issues identified
  • ·Multiple related PLC alarms persist after configuration fixes

Prevention

  • Always backup configuration before software updates
  • Document all custom strobe alias configurations
  • Use configuration version control for complex setups
  • Test PLC programs on target machine configurations before deployment

Common Mistakes

  • Forgetting to restart TNC after configuration changes
  • Case-sensitive alias type naming errors
  • Modifying configuration without proper backups
  • Assuming strobe configurations are portable between different machine types

Seeing Multiple Alarms?

Seeing another alarm with this one? Enter the code.

Get machine-aware diagnosis

AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.

Start free

Was this guide helpful?

Always verify with your machine manual or a certified technician before performing service procedures.