axismd.ai
Heidenhain Controller
Servo/Axis · Intermediate · 30-120 minutes
HEIDENHAIN 120-002E - Path not found
This alarm occurs exclusively when the TNC file system cannot resolve a path reference made by NC programs, PLC operations, or system configuration files. The root cause is always a mismatch between expected and actual file system structure, either due to deleted directories, incorrect path syntax, unmounted network drives, or removed storage media that was referenced in active operations.
HEIDENHAIN 120-002E - Path not found
Path not found
This TNC7/TNC 640 error (120-002E) relates to 'Path not found'. A required drive or directory was not found.
Root Cause Summary
This alarm occurs exclusively when the TNC file system cannot resolve a path reference made by NC programs, PLC operations, or system configuration files. The root cause is always a mismatch between expected and actual file system structure, either due to deleted directories, incorrect path syntax, unmounted network drives, or removed storage media that was referenced in active operations.
Safety
Causes and Fixes
Identify Referenced Path
Press PGM MGT key and open the NC program that was running when alarm occurred. Search for CALL PGM, FN18:, or SEL CYCLE commands and note the exact path string shown in '%1' from error message.
Use FIND function (GOTO key) and search for 'TNC:/' or 'SYS:/' to quickly locate all path references in program
Verify Directory Structure
Navigate in PGM MGT to the parent directory of the referenced path. Check if all subdirectories exist exactly as spelled in program (Heidenhain paths are case-sensitive).
TNC:/ is the user partition, SYS:/ is system partition - ensure you're checking the correct root directory
Correct Path or Create Directory
Either edit the NC program to reference correct existing path, or create the missing directory using NEW DIRECTORY soft key in PGM MGT. Copy required files to new location if needed.
Do not create directories in SYS:/ partition without machine manufacturer authorization as this may affect system configuration
Test Program Execution
Reset control with CE key, restart NC program in single block mode (SINGLE BLOCK key active) and verify path access works correctly when reaching CALL or FN18 command.
Call a technician if:
Prevention
Common Mistakes
Seeing Multiple Alarms?
Seeing another alarm with this one? Enter the code.
AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.
Start freeWas this guide helpful?
Always verify with your machine manual or a certified technician before performing service procedures.