HAAS Alarm 71 - Coolant Pump Pressure Low
Alarm 71 fires when the coolant pressure switch (typically set at 15-25 PSI) detects insufficient pressure from the coolant pump system. The NGC control monitors this switch through the machine I/O and will prevent spindle operation to protect cutting tools and spindle bearings from overheating.
HAAS Alarm 71 - Coolant Pump Pressure Low
Coolant pump pressure low
This alarm indicates the coolant system pressure switch has detected insufficient pressure at the coolant pump outlet. The IOCON board monitors the pressure switch input and triggers this fault when pressure remains below the setpoint for the programmed time delay. The machine will stop coolant flow commands and may prevent cycle start depending on the M-code configuration and parameter settings for coolant interlock.
Root Cause Summary
Alarm 71 fires when the coolant pressure switch (typically set at 15-25 PSI) detects insufficient pressure from the coolant pump system. The NGC control monitors this switch through the machine I/O and will prevent spindle operation to protect cutting tools and spindle bearings from overheating.
Safety
Causes and Fixes
Check coolant tank level
Open electrical cabinet door and visually inspect coolant tank. Level should be above minimum fill line (typically 2-3 inches from bottom).
Ensure machine is in EMERGENCY STOP before opening electrical cabinet
Refill coolant tank
Add appropriate coolant mixture (typically 5-10% concentration) until level reaches maximum fill line. Use only Haas-approved coolant or equivalent.
Check coolant concentration with refractometer - low concentration can cause biological growth and pump issues
Prime pump system
Press COOLANT button on control panel to manually activate pump and purge air from lines. Monitor pressure gauge if equipped.
May take 30-60 seconds to fully prime system after refill
Reset alarm and test
Press RESET button, then test coolant flow with M08 command in MDI mode.
Do not run spindle without confirmed coolant flow
Call a technician if:
Prevention
Common Mistakes