Fanuc Robot SRVO-072 - PMAL alarm (pulse coder fault)
SRVO-072 PMAL alarm indicates the pulse coder (encoder) has detected an internal hardware fault through its self-diagnostic routine. This alarm is triggered when the encoder's PMAL (Pulse coder Malfunction ALarm) signal activates due to internal electronics failure, contamination, battery-related data corruption, or physical damage to the encoder assembly.
Fanuc Robot SRVO-072 - PMAL alarm (pulse coder fault)
PMAL alarm (pulse coder fault)
The pulse coder (encoder) may be faulty. An internal diagnostic in the pulse coder has detected an abnormal condition in the encoder hardware.
Root Cause Summary
SRVO-072 PMAL alarm indicates the pulse coder (encoder) has detected an internal hardware fault through its self-diagnostic routine. This alarm is triggered when the encoder's PMAL (Pulse coder Malfunction ALarm) signal activates due to internal electronics failure, contamination, battery-related data corruption, or physical damage to the encoder assembly.
Safety
Causes and Fixes
Identify the affected axis
Check the alarm detail on the teach pendant under MENU > ALARM > F5 [DETAIL]. Note the specific axis number (J1-J6) generating the SRVO-072 alarm. Record the complete alarm history to identify if this is an intermittent or persistent fault.
If the alarm appears intermittently, check the alarm log timestamps (MENU > ALARM > F3 [HIST LOG]) to correlate with specific robot motions or environmental conditions like temperature changes.
Verify encoder feedback signals
Navigate to MENU > SYSTEM > F1 [TYPE] > Variables and check $POSN_FB[x] (position feedback) and $VEL_FB[x] (velocity feedback) for the affected axis. Compare values during slow jogging against expected encoder counts. Erratic or frozen values confirm encoder failure.
Enable deadman switch and use T1 mode at reduced speed (25% override) when jogging to verify feedback.
Check encoder cable and connections
Power down the robot controller completely. Inspect the encoder cable from the motor to the axis control board. Check connectors CN5A (motor side) and the corresponding axis connector on the servo amplifier for corrosion, bent pins, or loose connections. Measure cable continuity if physical damage is suspected.
Perform BZERO (cabinet zero) lockout procedure before accessing internal cabinet connections. Verify all E-stop circuits are engaged.
Replace the pulse coder
If diagnostics confirm encoder failure, replace the pulse coder assembly for the affected axis. After replacement, access MENU > SYSTEM > Variables and set $MCR.$SPC_RESET to TRUE (1) to reset the serial pulse coder data. This clears the encoder initialization flag.
Before removing the old encoder, record the current position from $POSN_FB and take a photo of any alignment marks. Some motors have witness marks for encoder alignment during reinstallation.
Re-master the axis and verify accuracy
After power cycling, perform single-axis mastering via MENU > SYSTEM > Master/Cal > F1 [SINGLE]. Use the Quick Master procedure if available, or master to mechanical reference. Verify mastering by jogging to known reference positions or tool calibration points and checking repeatability within ±0.02mm.
After mastering, run a slow test program with known positions and verify position error using $POS_ERR[x]. Values should remain under 0.05mm during motion. Use MENU > STATUS > POS_ERR to monitor real-time.