Fanuc Robot SRVO-130 - OHAL1 PS alarm (power supply overheat)
SRVO-130 OHAL1 PS alarm indicates the alpha iPS power supply module's heat sink has exceeded its thermal threshold. This is detected by an internal temperature sensor that triggers a protective shutdown to prevent component damage. The alarm will persist until the module cools sufficiently and the root cause of overheating is resolved.
Fanuc Robot SRVO-130 - OHAL1 PS alarm (power supply overheat)
OHAL1 PS alarm (power supply overheat)
The heat sink temperature of the main circuit of the Power Supply module (alpha iPS) is abnormally high. The power supply is overheating and must be allowed to cool before operation can resume.
Root Cause Summary
SRVO-130 OHAL1 PS alarm indicates the alpha iPS power supply module's heat sink has exceeded its thermal threshold. This is detected by an internal temperature sensor that triggers a protective shutdown to prevent component damage. The alarm will persist until the module cools sufficiently and the root cause of overheating is resolved.
Safety
Causes and Fixes
Visual and Audible Fan Inspection
With controller powered on (before alarm triggers if possible), open the cabinet door and visually confirm the alpha iPS cooling fan is spinning. Listen for abnormal bearing noise, grinding, or intermittent operation. The fan should run continuously during operation. Fan is typically located on the front or side of the power supply module.
Exercise caution when opening energized cabinets. Do not touch internal components. Only observe fan operation.
Check Fan Power Supply Voltage
Power down the controller and use a multimeter to verify fan power supply voltage at the fan connector. Alpha iPS fans typically operate at 24VDC or 200VAC depending on model. Check connector pins for corrosion or loose connections. Refer to power supply module maintenance manual (HW1484xxx series) for specific fan voltage specifications.
Disconnect main power and verify with voltage tester before checking connections.
Measure Fan Airflow
Use an anemometer or airflow indicator to measure actual airflow output from the cooling fan. Compare against specifications in the alpha iPS maintenance manual. Reduced airflow with fan running indicates bearing wear or internal obstruction.
Keep spare cooling fans in inventory. Fan replacement is straightforward and prevents extended downtime. Alpha iPS fans are field-replaceable without changing the entire module in most cases.
Inspect Fan Blades and Intake Vents
Check for dust accumulation, debris, or physical damage to fan blades. Inspect the intake vents on the power supply module for blockage. Even partial obstruction can reduce airflow by 30-40%, causing thermal issues during high-load operation.
Establish a preventive maintenance schedule for fan cleaning every 3-6 months in dusty environments. Use compressed air to clean, blowing from inside-out to avoid pushing debris deeper into the module.
Seeing Multiple Alarms?
Seeing another alarm with this one? Enter the code.
AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.
Start freeWas this guide helpful?
Always verify with your machine manual or a certified technician before performing service procedures.