Fanuc Robot SYST-001 - HOLD button is being pressed
SYST-001 HOLD button alarm indicates the robot's hold circuit is active, preventing program execution. This is an informational status alarm, not a fault condition. The hold state can be triggered by physical buttons, external I/O signals, programmed HOLD instructions, or UOP signals from integrated controllers.
Fanuc Robot SYST-001 - HOLD button is being pressed
HOLD button is being pressed
The HOLD button is currently pressed. The robot cannot run a program while HOLD is active. This is an informational alarm indicating the hold condition is preventing program execution.
Root Cause Summary
SYST-001 HOLD button alarm indicates the robot's hold circuit is active, preventing program execution. This is an informational status alarm, not a fault condition. The hold state can be triggered by physical buttons, external I/O signals, programmed HOLD instructions, or UOP signals from integrated controllers.
Safety
Causes and Fixes
Check teach pendant HOLD button
Inspect the yellow HOLD button on the teach pendant. Verify it is not stuck in the depressed position. The button should spring back when released. If stuck, the button mechanism may need replacement.
Do not disable hold functionality by bypassing buttons. HOLD is a critical safety feature for operator intervention.
Check operator panel HOLD button
Locate the HOLD button on the main operator panel (typically yellow or orange). Ensure it is in the released position and not mechanically jammed. Press and release to verify proper spring action.
Older panels may have accumulated dirt or adhesive residue causing buttons to stick. Clean around button housing with isopropyl alcohol.
Verify hold circuit continuity
Navigate to MENU > I/O > Signal > HOLD to view real-time hold circuit status. All hold inputs should show '0' (not active) when buttons are released. If showing '1' with no button pressed, suspect wiring or switch contact failure.
The hold circuit is series-connected. A fault anywhere in the chain will trigger this alarm.
Clear alarm and resume
After releasing the HOLD button, press the RESET button to clear the alarm. Press and hold CYCLE START to resume program execution. The alarm will immediately return if hold condition persists.