FANUC Controller
Servo/Axis · Intermediate · 30-90 minutes
Fanuc SV0443 - Servo alarm: n axis main circuit power failure
The FANUC SV0443 alarm typically indicates a failure of the servo converter cooling fan, often due to mechanical issues like bearing seizure or debris obstruction after years of operation. The most likely fix is replacing the fan with an OEM-specified part after confirming it no longer rotates or provides insufficient cooling. In rare cases, internal converter module faults may require professional service.
Fanuc SV0443 - Servo alarm: n axis main circuit power failure
SERVO ALARM: n AXIS MAIN CIRCUIT POWER FAILURE
The servo converter (power supply module) cooling fan has either stopped rotating or is running at insufficient RPM as detected by the fan's tachometer feedback circuit. This alarm prevents catastrophic thermal failure of the IGBTs and rectifier components in the converter module. Immediate action is required as continued operation without proper cooling will cause thermal shutdown or permanent damage to expensive power conversion components.
Root Cause Summary
The FANUC SV0443 alarm typically indicates a failure of the servo converter cooling fan, often due to mechanical issues like bearing seizure or debris obstruction after years of operation. The most likely fix is replacing the fan with an OEM-specified part after confirming it no longer rotates or provides insufficient cooling. In rare cases, internal converter module faults may require professional service.
Safety
Causes and Fixes
Visual and Audible Fan Check
With machine power ON, observe the converter module fan for the affected axis. Listen for fan noise and visually confirm if blades are rotating. Note any grinding sounds indicating bearing failure.
Use a flashlight to inspect through the fan grille for debris like dust clumps or metal shavings that could jam the blades.
Do not touch the fan while powered ON due to risk of injury from moving parts.
Manual Rotation Test
Power OFF the CNC and wait 5 minutes for capacitor discharge. Manually spin the fan blades with a gloved hand or plastic tool to check for resistance or roughness. A seized fan will not spin freely.
If the fan feels gritty or stuck, apply a small amount of compressed air to dislodge minor debris before retesting.
Ensure E-stop is engaged and LOTO procedures are followed before physical inspection.
Fan Replacement
If the fan is seized or rotates poorly, replace it with an OEM-specified part matching voltage (typically 24VDC) and CFM rating as per amplifier manual. Securely connect the new fan and power ON to verify operation.
Keep a spare fan on hand for critical machines to minimize downtime during replacement.
Use only manufacturer-approved fans; mismatched specs can lead to insufficient cooling and further alarms.
Call a technician if:
Prevention
Common Mistakes
Seeing Multiple Alarms?
Seeing another alarm with this one? Enter the code.
AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.
Start freeWas this guide helpful?
Always verify with your machine manual or a certified technician before performing service procedures.