Fanuc SV0421 - Servo alarm: n axis excess position deviation
The FANUC SV0421 alarm typically results from a discrepancy between primary and secondary feedback devices in dual-position feedback systems, often due to mechanical failures or linear scale issues. The most likely fix involves inspecting and correcting mechanical transmission components or replacing a faulty linear scale. Systematic troubleshooting of feedback devices and parameters usually resolves the issue.
Fanuc SV0421 - Servo alarm: n axis excess position deviation
SERVO ALARM: n AXIS EXCESS POSITION DEVIATION
The control has detected that the position error between the commanded position and actual position has exceeded the allowable limit (Parameter 1828) on the specified axis during dual-position feedback operation. Dual feedback uses two separate position encoders (typically one on the motor and one on the ballscrew/table) to detect mechanical errors. This alarm indicates a significant discrepancy between the two feedback devices or mechanical transmission failure.
Root Cause Summary
The FANUC SV0421 alarm typically results from a discrepancy between primary and secondary feedback devices in dual-position feedback systems, often due to mechanical failures or linear scale issues. The most likely fix involves inspecting and correcting mechanical transmission components or replacing a faulty linear scale. Systematic troubleshooting of feedback devices and parameters usually resolves the issue.
Safety
Causes and Fixes
Inspect Coupling and Ballscrew
Disable servo power and engage axis brakes. Remove the motor coupling cover and visually inspect for wear, cracks, or loose set screws. Check ballscrew for visible damage or bending.
Use a flashlight and mirror to inspect hard-to-reach areas of the coupling for hairline cracks.
Ensure Emergency Stop is active to prevent unexpected axis movement during inspection.
Measure Backlash
Use a dial indicator mounted on the table or spindle to measure backlash while manually rotating the ballscrew. Backlash exceeding 0.02mm indicates wear or damage requiring repair or replacement.
Mark the ballscrew with a marker to track rotation and ensure accurate measurement.
Secure the axis mechanically if working on a vertical axis to prevent gravity-driven movement.
Test Manual Movement
Disconnect the motor from the ballscrew (if safe) and manually rotate the ballscrew while observing the linear scale position on the ABSOLUTE screen. Inconsistent or no position change indicates mechanical binding or failure.
If manual rotation feels uneven, apply light lubrication to isolate friction from binding.
Counterbalance vertical axes before disconnecting motor to avoid sudden drops.
Call a technician if:
Prevention
Common Mistakes
Seeing Multiple Alarms?
Seeing another alarm with this one? Enter the code.
AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.
Start freeWas this guide helpful?
Always verify with your machine manual or a certified technician before performing service procedures.