Fanuc Alarm 764 - SPINDLE-2 ABNORMAL TORQUE ALARM
Fanuc Alarm 764 indicates the spindle amplifier has detected torque exceeding the configured limit on the second spindle (SP2). This protection feature monitors spindle load via parameter settings and triggers when actual torque exceeds the threshold defined in parameters 4260-4265, typically due to mechanical binding, excessive cutting load, or amplifier/motor issues.
Fanuc Alarm 764 - SPINDLE-2 ABNORMAL TORQUE ALARM
SPINDLE ALARM 764
Abnormal torque was detected in spindle 2. Check for mechanical binding or excessive cutting forces on the second spindle.
Root Cause Summary
Fanuc Alarm 764 indicates the spindle amplifier has detected torque exceeding the configured limit on the second spindle (SP2). This protection feature monitors spindle load via parameter settings and triggers when actual torque exceeds the threshold defined in parameters 4260-4265, typically due to mechanical binding, excessive cutting load, or amplifier/motor issues.
Causes and Fixes
Navigate to DIAGNOSIS > SPINDLE screen (PMC or Spindle tab depending on control series). Monitor current load percentage for SP2 while manually jogging spindle at low RPM (M43 or direct MDI command). Normal load should be under 20% with no tool/workpiece.
Manually rotate spindle 2 by hand with E-stop pressed and spindle motor power OFF. Check for grinding, tight spots, or complete seizure. Inspect drawbar mechanism, tool holder interface, and collet closer for debris or damage.
Lock out main power and verify motor is de-energized before manual rotation
Remove tool holder and workpiece from SP2. Clear alarm and test spindle with M code command (M43 S500 for SP2 at 500 RPM). If alarm clears without load, inspect bearings, preload adjustment, and lubrication system. Check grease levels and automatic lubrication operation if equipped.
Check spindle orientation (C-axis) encoder feedback if equipped. Navigate to DIAGNOSIS > PARAMETER and verify SP2 position encoder signals are stable. Misaligned or failing encoder can cause orientation hunting and excessive torque during positioning.
Call a technician if:
Prevention
Common Mistakes
Seeing Multiple Alarms?
Seeing another alarm with this one? Enter the code.
AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.
Start freeWas this guide helpful?
Always verify with your machine manual or a certified technician before performing service procedures.