Fanuc Alarm 373 - ILLEGAL HIGH-SPEED SKIP SIGNAL
Alarm 373 occurs in multi-path/multi-channel machining centers when two or more paths attempt to use the same high-speed skip signal (G31) simultaneously, or when the same skip signal number is assigned to multiple paths in parameters. This is a configuration conflict in synchronized multi-path operations where skip signal assignments must be unique per path.
Fanuc Alarm 373 - ILLEGAL HIGH-SPEED SKIP SIGNAL
SYSTEM ALARM 373
Fanuc alarm 373: SYSTEM ALARM 373. This alarm indicates a fault condition detected by the Fanuc control. Refer to the alarm number and name to identify the specific system or function involved.
Root Cause Summary
Alarm 373 occurs in multi-path/multi-channel machining centers when two or more paths attempt to use the same high-speed skip signal (G31) simultaneously, or when the same skip signal number is assigned to multiple paths in parameters. This is a configuration conflict in synchronized multi-path operations where skip signal assignments must be unique per path.
Causes and Fixes
Review the program blocks immediately before alarm occurrence. Check all active G31 commands across all paths. Verify if G31 P1, G31 P2, etc. use different P-numbers for each simultaneous path operation.
Navigate to SYSTEM > PROGRAM on each path controller display. List active programs on all paths and identify synchronized or simultaneous skip operations. Document which G31 Pn signal each path uses.
Modify NC program to assign unique skip signal numbers to each path. For example: Path 1 uses G31 P1, Path 2 uses G31 P2, Path 3 uses G31 P3. Ensure physical skip probe signals are wired to corresponding separate inputs.
Verify skip signal physical input assignments in DIAGNOSIS > PARAMETER > G31 SKIP or check parameters 6200-6207 series (skip signal input numbers). Confirm each path references different X-address input points for their respective skip signals.
Call a technician if: