FANUC codes
FANUCProgram/G-codeIntermediate30-60 minutes

373

Fanuc Alarm 373 - ILLEGAL HIGH-SPEED SKIP SIGNAL

SYSTEM ALARM 373

Fanuc alarm 373: SYSTEM ALARM 373. This alarm indicates a fault condition detected by the Fanuc control. Refer to the alarm number and name to identify the specific system or function involved.

Root Cause Summary

Alarm 373 occurs in multi-path/multi-channel machining centers when two or more paths attempt to use the same high-speed skip signal (G31) simultaneously, or when the same skip signal number is assigned to multiple paths in parameters. This is a configuration conflict in synchronized multi-path operations where skip signal assignments must be unique per path.

Causes and Fixes

  1. 1

    Review the program blocks immediately before alarm occurrence. Check all active G31 commands across all paths. Verify if G31 P1, G31 P2, etc. use different P-numbers for each simultaneous path operation.

  2. 2

    Navigate to SYSTEM > PROGRAM on each path controller display. List active programs on all paths and identify synchronized or simultaneous skip operations. Document which G31 Pn signal each path uses.

  3. 3

    Modify NC program to assign unique skip signal numbers to each path. For example: Path 1 uses G31 P1, Path 2 uses G31 P2, Path 3 uses G31 P3. Ensure physical skip probe signals are wired to corresponding separate inputs.

  4. 4

    Verify skip signal physical input assignments in DIAGNOSIS > PARAMETER > G31 SKIP or check parameters 6200-6207 series (skip signal input numbers). Confirm each path references different X-address input points for their respective skip signals.

DIY Feasiblehigh confidence

Call a technician if:

  • ·PMC ladder logic modifications required
  • ·Multi-path parameter changes needed
  • ·Custom macro debugging beyond basic level

Prevention

  • Document skip signal assignments in program headers
  • Use consistent signal numbering conventions across all programs
  • Implement signal usage validation in custom macros
  • Regular review of multi-path program coordination

Common Mistakes

  • Copying G31 commands without changing signal numbers
  • Not considering background process signal usage
  • Ignoring multi-path signal conflicts
  • Using variables for signal selection without validation

Related Alarms

Seeing Multiple Alarms?

Seeing another alarm with this one? Enter the code.

Get machine-aware diagnosis

AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.

Start free

Was this guide helpful?

Always verify with your machine manual or a certified technician before performing service procedures.