
axismd.ai
FANUC Controller
Program/G-code · Basic · 10-20 minutes
Fanuc Alarm 1092 - DUPLICATE MACRO-CALL WORD
Alarm 1092 occurs when multiple macro call instructions (G65/G66/G67 or user macro calls) are specified within a single NC program block. The Fanuc control can only execute one macro call per block and flags this as a programming error when it detects duplicate or conflicting macro call commands in the same line.
Fanuc Alarm 1092 - DUPLICATE MACRO-CALL WORD
SYSTEM ALARM 1092
Fanuc alarm 1092: SYSTEM ALARM 1092. This alarm indicates a fault condition detected by the Fanuc control. Refer to the alarm number and name to identify the specific system or function involved.
Root Cause Summary
Alarm 1092 occurs when multiple macro call instructions (G65/G66/G67 or user macro calls) are specified within a single NC program block. The Fanuc control can only execute one macro call per block and flags this as a programming error when it detects duplicate or conflicting macro call commands in the same line.
Causes and Fixes
At the MDI/EDIT screen, press PRGRM key and locate the block number where alarm 1092 occurred. The cursor will typically be positioned at the error line.
Examine the block for multiple G65 or G66 commands. Example of error: 'G65 P1000 A10 G65 P2000 B20'. Identify which macro calls are duplicated.
Separate macro calls into individual blocks. Correct format: 'G65 P1000 A10;' on one line, then 'G65 P2000 B20;' on the next line.
Reset the alarm by pressing RESET key, then re-run the program in single block mode to verify correct macro execution sequence.
Call a technician if:
Prevention
Common Mistakes
Seeing Multiple Alarms?
Seeing another alarm with this one? Enter the code.
AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.
Start freeWas this guide helpful?
Always verify with your machine manual or a certified technician before performing service procedures.