Fanuc Alarm 1097 - TOO LONG VARIABLE NAME
Fanuc Alarm 1097 occurs when a macro variable name exceeds the maximum character length permitted by the control system. This typically happens in custom macro programs using #variable naming or when user-defined macro variable names (accessible via SYSTEM > MACRO > COMMON VARIABLE) exceed system limits, which are typically 8 characters for local variables and 32 characters for common variables depending on control series.
Fanuc Alarm 1097 - TOO LONG VARIABLE NAME
SYSTEM ALARM 1097
Fanuc alarm 1097: SYSTEM ALARM 1097. This alarm indicates a fault condition detected by the Fanuc control. Refer to the alarm number and name to identify the specific system or function involved.
Root Cause Summary
Fanuc Alarm 1097 occurs when a macro variable name exceeds the maximum character length permitted by the control system. This typically happens in custom macro programs using #variable naming or when user-defined macro variable names (accessible via SYSTEM > MACRO > COMMON VARIABLE) exceed system limits, which are typically 8 characters for local variables and 32 characters for common variables depending on control series.
Causes and Fixes
Access MDI or EDIT mode and locate the program line causing the alarm. The alarm typically displays the program number and sequence number where the error occurred.
Review all macro variable declarations in the program. Check #_variable names for length compliance: local variables max 8 characters, common variables typically max 32 characters (check Parameter 6031 for actual system limits on common variable names).
Shorten the variable name to meet system requirements while maintaining program logic. Example: change #_LONG_TOOLING_OFFSET_VALUE to #_TOOLOFS or use numbered variables like #500 instead of named variables.
Verify Parameter 6001 bit 0 (MACEX) is enabled to confirm macro executor capability. Reset alarm and test program execution in single block mode to verify correction.
Call a technician if:
Prevention
Common Mistakes
Seeing Multiple Alarms?
Seeing another alarm with this one? Enter the code.
AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.
Start freeWas this guide helpful?
Always verify with your machine manual or a certified technician before performing service procedures.