Fanuc Alarm 1095 - TOO MANY TYPE-2 ARGUMENT
Alarm 1095 occurs when a custom macro program contains more than ten sets of I, J, K arguments specified as type-II (indirect) arguments within a single macro call or block. This violates Fanuc's macro programming specification limits for argument array addressing, typically seen in user-defined G-code or M-code macros when excessive loop iterations or array indexing is attempted.
Fanuc Alarm 1095 - TOO MANY TYPE-2 ARGUMENT
SYSTEM ALARM 1095
Fanuc alarm 1095: SYSTEM ALARM 1095. This alarm indicates a fault condition detected by the Fanuc control. Refer to the alarm number and name to identify the specific system or function involved.
Root Cause Summary
Alarm 1095 occurs when a custom macro program contains more than ten sets of I, J, K arguments specified as type-II (indirect) arguments within a single macro call or block. This violates Fanuc's macro programming specification limits for argument array addressing, typically seen in user-defined G-code or M-code macros when excessive loop iterations or array indexing is attempted.
Causes and Fixes
Press EDIT key, search for the program number displayed with alarm 1095 (typically shown as program name or O-number in alarm message). Navigate to PROGRAM screen and locate the specific N-block number if referenced.
Examine the macro call statement for I, J, K arguments using indirect addressing (e.g., I#100 J#101 K#102 repeated more than 10 times). Count all I, J, K argument pairs/sets within the single block or G65 macro call statement.
Restructure the macro program to reduce type-II argument sets to 10 or fewer. Break complex calculations into multiple macro calls using G65 P____ with separate argument sets, or use direct assignment to local variables within the macro body instead.
Ensure macro variable numbers (#100-#199 for local variables, #500-#999 for common variables) are correctly referenced per Fanuc macro programming standards.
Verify parameter 6000#0 (macro executor enable) is set to 1 if alarm persists. Reset alarm using RESET key and re-execute program in single block mode (press SINGLE BLOCK key) to confirm correction.
Call a technician if:
Prevention
Common Mistakes
Seeing Multiple Alarms?
Seeing another alarm with this one? Enter the code.
AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.
Start freeWas this guide helpful?
Always verify with your machine manual or a certified technician before performing service procedures.