087

Fanuc Alarm 087 - BUFFER OVERFLOW

BUFFER OVERFLOW

Fanuc PS087: A buffer overflow occurred on the RS-232 serial communication interface. The receive buffer was filled faster than the control could process the data.

Root Cause Summary

Alarm 087 BUFFER OVERFLOW occurs when the CNC reader/punch interface receives more than 10 characters after issuing a read stop command, indicating the external device (tape reader, PC, DNC system) is not responding to XON/XOFF or DC codes properly. This is a hardware handshaking failure between the CNC and the external communication device on the reader/punch channel.

Safety

  • Stop machining operations immediately - buffer overflow may cause program execution errors or unexpected machine behavior
  • Ensure the machine is in a safe state before attempting any troubleshooting steps. Stop the program and power down the spindle.
  • Be cautious when working with electrical connections. Power down the machine before disconnecting or reconnecting any cables.
  • Refer to the CNC machine's safety manual for specific safety precautions.
  • Incorrect parameter changes can lead to unexpected machine behavior. Back up parameters before making any changes.
  • Be aware of moving parts when the machine is powered on.

Causes and Fixes

  1. 1

    Navigate to SYSTEM > PARAM and verify Parameter 20 (input device selection) is set correctly: 0=tape reader, 1=RS232C reader/punch interface. Confirm Parameter 21 bit settings for stop code selection match the external device configuration.

  2. 2

    Check Parameters 100-109 (RS232C channel 0 settings). Verify Param 102 bit 0 (DC code enable) is set to 1 to enable XON/XOFF handshaking. Confirm baud rate (Param 100), stop bits (Param 101 bit 0-1), and parity (Param 101 bit 2-4) match external device.

  3. 3

    Test external device software settings. Ensure DNC software or communication program has XON/XOFF flow control enabled, not set to NONE or hardware-only handshaking. Send a small test file (under 80 characters) to isolate the issue.

  4. 4

    If using RS232 cable, verify cable is properly wired for software handshaking with TX, RX, and GND connected. Check cable continuity and ensure no cross-wiring. Replace cable if suspect.

DIY Feasiblehigh confidence

Call a technician if:

  • ·I/O board hardware replacement needed
  • ·Parameter corruption requiring system restore
  • ·Multiple communication alarms occurring simultaneously

Prevention

  • Regularly verify communication parameter settings match external devices
  • Use quality shielded RS-232C cables
  • Implement proper grounding between CNC and external equipment
  • Keep DNC software updated with latest communication protocols

Common Mistakes

  • Assuming all RS-232C devices use same handshaking method
  • Ignoring baud rate timing requirements
  • Using incorrect cable pinout for specific application
  • Not verifying external device buffer capabilities

Related Alarms

Seeing Multiple Alarms?

Seeing another alarm with this one? Enter the code.

Get machine-aware diagnosis

AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.

Start free

Was this guide helpful?

Always verify with your machine manual or a certified technician before performing service procedures.