Fanuc Alarm 085 - OVERRUN ERROR
Fanuc Alarm 085 (Communication Timeout) indicates the CNC has failed to receive expected data from an external device within the programmed timeout period. This typically occurs during serial communication (RS-232C, HSSB, Ethernet) between the CNC and peripheral equipment such as DNC systems, robots, PLCs, or bar feeders. The alarm triggers when handshake signals are not received or data transmission is interrupted beyond the timeout threshold defined in communication parameters.
Fanuc Alarm 085 - OVERRUN ERROR
OVERRUN ERROR
Fanuc PS085: An overrun error occurred on the RS-232 serial communication interface. Data was received faster than the control could process it, causing characters to be lost.
Root Cause Summary
Fanuc Alarm 085 (Communication Timeout) indicates the CNC has failed to receive expected data from an external device within the programmed timeout period. This typically occurs during serial communication (RS-232C, HSSB, Ethernet) between the CNC and peripheral equipment such as DNC systems, robots, PLCs, or bar feeders. The alarm triggers when handshake signals are not received or data transmission is interrupted beyond the timeout threshold defined in communication parameters.
Safety
Causes and Fixes
Navigate to SYSTEM > PARAM and verify parameter 0020 (baud rate: 0=300, 4=4800, 5=9600, 6=19200), parameter 0021 (stop bits: 0=1bit, 1=2bits), and parameter 0022 (parity: 0=none, 1=odd, 2=even) match the external device settings.
Check parameter 0000 bit 0 (I/O channel selection) and parameter 0020 bit 2 (TV check) settings. Verify parameter 0101 (timeout value) - increase from default if network latency is high, typical range 1-60 seconds.
Changing parameter 0000 requires power cycle to take effect
Verify parameter 0112 (DC code settings) and parameter 0110 (end-of-block code). For DNC operations, confirm parameter 0100 bit 0 (EIA/ISO code) matches the data format being transmitted.
Test communication by navigating to SYSTEM > I/O and attempting manual data input/output. Monitor DIAGNOSIS > I/O for real-time communication status and handshake signal states (DR, ER, SR).
Call a technician if:
Prevention
Common Mistakes
Seeing Multiple Alarms?
Seeing another alarm with this one? Enter the code.
AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.
Start freeWas this guide helpful?
Always verify with your machine manual or a certified technician before performing service procedures.