axismd.ai
Siemens SINUMERIK Controller
Parameter · Intermediate · 30-45 minutes
Siemens 840D 61423 - Channel block: Parameter _TNUM not agreed or not created
The alarm can be triggered by the following measuring cycles: CYCLE996 Remedy: Causes of error: 1. Parameter CYCLE996 _TNUM incorrect or equals zero 2. No swivel data record created -> MD18088 = 0
Siemens 840D 61423 - Channel block: Parameter _TNUM not agreed or not created
Channel block: Parameter _TNUM not agreed or not created
The alarm can be triggered by the following measuring cycles: CYCLE996 Remedy: Causes of error: 1. Parameter CYCLE996 _TNUM incorrect or equals zero 2. No swivel data record created -> MD18088 = 0
Safety
Common Causes
Troubleshooting Steps
Seeing Multiple Alarms?
Seeing another alarm with this one? Enter the code.
AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.
Start freeWas this guide helpful?
Always verify with your machine manual or a certified technician before performing service procedures.