The alarm can be triggered by the following measuring cycles: CYCLE974, CYCLE994, CYCLE977, CYCLE978, CYCLE979, CYCLE997, CYCLE998 Remedy: The workpiece probe must be calibrated according to its type and use.
Channel block: Check calibration of multi/mono probes.
The alarm can be triggered by the following measuring cycles: CYCLE974, CYCLE994, CYCLE977, CYCLE978, CYCLE979, CYCLE997, CYCLE998 Remedy: The workpiece probe must be calibrated according to its type and use.
Safety
Refer to Siemens documentation
Ensure qualified technician performs repairs
Common Causes
Workpiece probe has not been calibrated or calibration data is outdated
Probe calibration values do not match the actual probe type installed
Probe worn or damaged, requiring recalibration or replacement
Incorrect probe configuration parameters in the measuring cycle setup
Probe signal integrity issue preventing accurate calibration data capture
Troubleshooting Steps
1Verify the probe type installed matches the probe type specified in the measuring cycle parameters; consult machine documentation for correct probe identification
2Execute the probe calibration routine appropriate for your probe type (mono or multi-probe) using the machine's calibration wizard or manual calibration procedure
3Inspect probe tip for wear, damage, or contamination; clean or replace probe if mechanical damage is visible
4Confirm calibration data has been saved to the correct NC parameter location and that the measuring cycle is referencing the correct calibration data
5Test probe functionality with a simple trigger test before re-running the measuring cycle to confirm signal response