Siemens 61357 - No resources free

No resources free

Not enough NC memory space available or too many files / directories in the NC file system Control reaction: Interpreter stop NC Start disable in this channel. Interface signals are set. Alarm display.

Safety

  • Only qualified personnel should diagnose and clear control alarms; follow the machine builder's safety procedures and lockout/tagout where hardware work is required.

Common Causes

  • Not enough NC memory space available or too many files / directories in the NC file system

Troubleshooting Steps

  1. 1Delete or unload files MD18270: $MN_MM_NUM_SUBDIR_PER_DIR, MD18280: $MN_MM_NUM_FILES_PER_DIR or MD18320: Check $MN_MM_NUM_FILES_IN_FILESYSTEM and increase if necessary.
  2. 2Clear alarm with the RESET key. Restart part program