Siemens SINUMERIK codes
Siemens SINUMERIKServo/AxisIntermediate30-60 minutes

61134

Siemens 61134 - Block : Rotary axis parameters incorrect, check values for rotary

Block: Rotary axis parameters incorrect, check values for rotary

Control reaction: Interpreter stop NC Start disable in this channel. Interface signals are set. Alarm display.

Safety

  • Only qualified personnel should diagnose and clear control alarms; follow the machine builder's safety procedures and lockout/tagout where hardware work is required.

Troubleshooting Steps

  1. 1Clear alarm with the RESET key. Restart part program Continuation: Alarms

Seeing Multiple Alarms?

Seeing another alarm with this one? Enter the code.

Get machine-aware diagnosis

AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.

Start free

Was this guide helpful?

Always verify with your machine manual or a certified technician before performing service procedures.