Siemens 840D 4632 - Logical PROFIBUS handwheel slot base address for handwheel not
Alarm 4632 fires when the NCK cannot resolve the logical PROFIBUS handwheel slot base address for a configured handwheel module. This occurs because the address specified in $MN_HANDWHEEL_LOGIC_ADDRESS[] array does not correspond to an actual PROFIBUS slot allocation in the machine data configuration, breaking the communication path between the 840D controller and the handwheel interface.
Siemens 840D 4632 - Logical PROFIBUS handwheel slot base address for handwheel not
Logical PROFIBUS handwheel slot base address for handwheel not
Siemens SINUMERIK 840D system notice 4632: Logical PROFIBUS handwheel slot base address for handwheel not. This is a system-level notification regarding machine data or configuration. Note the message details and take the indicated action.
Root Cause Summary
Alarm 4632 fires when the NCK cannot resolve the logical PROFIBUS handwheel slot base address for a configured handwheel module. This occurs because the address specified in $MN_HANDWHEEL_LOGIC_ADDRESS[] array does not correspond to an actual PROFIBUS slot allocation in the machine data configuration, breaking the communication path between the 840D controller and the handwheel interface.
Safety
Causes and Fixes
Access Diagnostics > Machine Data > Handwheel Configuration. Locate $MN_HANDWHEEL_LOGIC_ADDRESS[%1] and note the logical base address value.
Navigate to Commissioning > PROFIBUS > IO Configuration and verify that a PROFIBUS slot with matching logical base address exists and is assigned to the handwheel module. Cross-reference against $MN_HANDWHEEL_MODULE index.
If no matching slot exists, the address in $MN_HANDWHEEL_LOGIC_ADDRESS must be corrected or a new PROFIBUS IO slot must be created.
Correct the logical address in machine data to match the actual PROFIBUS slot base address, then perform a cold restart (mode: Editor, press CTRL+SHIFT+DEL to clear NCK memory).
Improper restart may leave corrupted cache; use full power cycle if cold restart fails.
After restart, verify handwheel communication in Diagnostics > PROFIBUS > Module Status. Confirm the handwheel slot shows 'Ready' or 'Online' status.