Siemens SINUMERIK codes
Siemens SINUMERIKServo/AxisIntermediate30-45 minutes

4113

Siemens 840D 4113 - Sysclock cycle changed to ms

Sysclock cycle changed to ms

MD 10050 SYSCLOCK_CYCLE_TIME has been modified on systems with PROFIBUS DP because of the modified DP cycle in SDB-Type-2000.

Safety

  • Refer to Siemens documentation
  • Ensure qualified technician performs repairs

Common Causes

  • PROFIBUS DP cycle time was modified in the slave data block (SDB-Type-2000) without corresponding update to MD 10050
  • Automatic sysclock adjustment triggered by DP cycle change detection during system startup or parameter download
  • Mismatch between configured PROFIBUS DP master cycle and slave device cycle requirements
  • Parameter synchronization failure between PROFIBUS configuration and machine data settings

Troubleshooting Steps

  1. 1Verify the new sysclock cycle time value (%1) matches your intended PROFIBUS DP cycle configuration in the SDB-Type-2000 block
  2. 2Compare current MD 10050 SYSCLOCK_CYCLE_TIME value against PROFIBUS DP cycle settings in your hardware configuration tool
  3. 3Review recent changes to PROFIBUS DP slave data blocks and re-download the complete configuration to ensure synchronization
  4. 4Check PROFIBUS DP diagnostics for cycle time conflicts or timing violations between master and slave devices
  5. 5If the new sysclock value is incorrect, restore the intended MD 10050 value and update the SDB-Type-2000 DP cycle to match, then perform a complete parameter download and cold restart