Siemens SINUMERIK codes
Siemens SINUMERIKServo/AxisIntermediate30-45 minutes

4150

Siemens 840D 4150 - Channel invalid M function subprogram call configured

Channel invalid M function subprogram call configured

The machine data $MN_M_NO_FCT_CYCLE[n] or $MN_M_NO_FCT_CYCLE_PAR contains invalid configration data: An M function, which is used by the system and can not be replaced by a subprogram call has been specified in the machine data $MN_M_NO_FCT_CYCLE[n] for the configuration of the subprogram call via M

Safety

  • Refer to Siemens documentation
  • Ensure qualified technician performs repairs

Common Causes

  • M function assigned in $MN_M_NO_FCT_CYCLE[n] is a reserved system M code that cannot be overridden by subprogram
  • Machine data parameter contains M function number outside valid range for subprogram substitution
  • Incorrect machine data configuration attempting to redirect a critical M function (such as M0, M1, M2, M30) through custom subprogram
  • Corrupted or manually edited machine data file with invalid M function reference
  • Mismatch between configured M function and channel capabilities in multi-channel configuration

Troubleshooting Steps

  1. 1Access machine data editor and review $MN_M_NO_FCT_CYCLE[n] parameter to identify which M function number is causing the conflict
  2. 2Consult the Siemens 840D/828D documentation to verify which M functions are reserved and cannot be substituted with subprograms
  3. 3Remove or replace the invalid M function assignment with a valid M code that is not system-reserved (typically M20-M99 range depending on configuration)
  4. 4Verify the subprogram name and path associated with the M function are correctly formatted and accessible to the control
  5. 5Perform a machine data consistency check and reload configuration, then test the M function call in manual mode